other:dsx:calibratedsx:tutorials:collect_calibration_images
Differences
This shows you the differences between two versions of the page.
Next revision | Previous revision | ||
other:dsx:calibratedsx:tutorials:collect_calibration_images [2024/07/12 13:55] – created sgranger | other:dsx:calibratedsx:tutorials:collect_calibration_images [2025/02/15 06:41] (current) – Cleaned up page and swapped content with "Digitize Points of Interest" since the content and titles had gotten mixed up. wikisysop | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== | + | ====== |
- | To digitize a point of interest (POI) on a calibration | + | This tutorial discusses considerations for collecting quality |
- | If you make a mistake identifying the proper POI in the first view, you can press the //Esc// key to cancel the process. If you make a mistake after identifying the POI in the second view, you can remove the POI pose by unchecking the //pose// box in the POI table. Once you have digitized a POI, CalibrateDSX automatically advances the current POI to the next one in the table that does not already have a pose (unless the // | + | ===== Terminology ===== |
- | Many calibration objects contain too many beads to manually identify in the X-ray images. These objects usually contain a small number of " | + | The //voltage// across |
- | Once you have identified the POIs for one or more reporting times, you can have CalibrateDSX attempt to automatically identify them for other reporting times using the //Propagate POIs// command | + | The //current// through the cathode filament is usually measured |
- | **Note**: If you hold down the **Alt** key while the POI cursor is displayed over an X-ray image, the cyan point inside the circle will display the location that the centroid-finding algorithm would calculate if you left-clicked with the cursor in its current position. This point will update in real-time as you move the cursor. If the point is not visible inside the yellow square, it means either there is no suitable location of a POI centroid, or that region of the image has been masked by a previously digitized POI. | + | ===== Determining Settings ===== |
- | **Note**: | + | To determine |
- | + | ||
- | **Note**: When digitizing a POI, all previously digitized POIs on the image are masked out, so that no two POIs can be located | + | |
+ | Also, any stationary objects that will be in the field of view during subject data collection (e.g., stands, tables, graduated filters) should be in place for the calibration trials as well. | ||
+ | ===== See Also ===== | ||
+ | Go back to an overview of [[other: |
other/dsx/calibratedsx/tutorials/collect_calibration_images.1720792533.txt.gz · Last modified: 2024/07/12 13:55 by sgranger