User Tools

Site Tools


visual3d:documentation:pipeline:file_commands:import_signals_from_c3d_file

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
visual3d:documentation:pipeline:file_commands:import_signals_from_c3d_file [2024/06/19 14:00] – created sgrangervisual3d:documentation:pipeline:file_commands:import_signals_from_c3d_file [2025/09/10 18:05] (current) wikisysop
Line 1: Line 1:
-Imports signals from a [[Visual3D:Documentation:C3D_Signal_Types:C3D_Format|C3D]] file into the Active File+===== Import Signals From C3D File===== 
 +====Overview==== 
 +This command imports signals from a [[Visual3D:Documentation:C3D_Signal_Types:C3D_Format|C3D]] file into the active file.
  
-**Import_Signals_From_C3D_File**+<code> 
 +Import_Signals_From_C3D_File**
 ! /FILE_NAME= ! /FILE_NAME=
 ! /IMPORT_FILE_NAME= ! /IMPORT_FILE_NAME=
Line 17: Line 20:
 ! /IMPORT_FORCE_PLATFORM_PARAMETERS=FALSE ! /IMPORT_FORCE_PLATFORM_PARAMETERS=FALSE
 ! /ADD_PREFIX_TO_IMPORT= ! /ADD_PREFIX_TO_IMPORT=
-**;** +
-**NOTE:** Only ANALOG and ROTATION signals can be imported. SYNCH Pulses are assumed to be analog signals.+</code>
  
-If analog signals already exist in the c3d file, and the imported analog signals are at a different sampling rate, these new signals must be imported as DERIVED signals.+====Command Parameters==== 
 +|**Parameter**   |**Description**| 
 +|**! /FILE_NAME=**|Name of your file| 
 +|**! /IMPORT_FILE_NAME=**|Name of your file| 
 +|**! /REPLACE_EXISTING_SIGNALS=**|Override existing signals with same name| 
 +|**! /SYNCH_OFFSET=**|Assumed to be analog signals| 
 +|**! /IMPORT_ANALOG_SYNCH=**|Only ANALOG and ROTATION signals can be imported.| 
 +|**! /IMPORT_ANALOG_THRESHOLD=**|0.0| 
 +|**! /IMPORT_ANALOG_ASCENDING=**|True| 
 +|**! /ANALOG_RATE=**|If analog signals already exist in the c3d file, and the imported analog signals are at a different sampling rate, these new signals must be imported as DERIVED signals.
 +|**! /ANALOG_RATIO=**| 
 +|**! /ALLOW_RESAMPLE==**|Allow to resample the sampling rate| 
 +|**! /INTERPOLATION_METHOD=**|CUBIC_SPLINE| 
 +|**! /IMPORT_AS_DERIVED=**|If sampling rate is different, this should be TRUE| 
 +|**! /DERIVED_FOLDER=**|Location of derived folder| 
 +|**! /IMPORT_FORCE_PLATFORM_PARAMETERS=**|If force platform is used, import here| 
 +|**! /ADD_PREFIX_TO_IMPORT=**||
  
-\\ 
-[[Visual3D:Documentation:Pipeline:General_Information:Pipeline_Commands_Reference|Back to Pipeline Commands Reference]] 
  
 +==== Example ====
  
 +Under construction...
 +
 +[[Visual3D:Documentation:Pipeline:General_Information:Pipeline_Commands_Reference|Back to Pipeline Commands Reference]]
  
visual3d/documentation/pipeline/file_commands/import_signals_from_c3d_file.1718805613.txt.gz · Last modified: 2024/06/19 14:00 by sgranger