User Tools

Site Tools


visual3d:documentation:pipeline:model_based_data_commands:units_of_measurement

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
visual3d:documentation:pipeline:model_based_data_commands:units_of_measurement [2024/06/17 18:21] – created sgrangervisual3d:documentation:pipeline:model_based_data_commands:units_of_measurement [2025/04/29 14:09] (current) – Converted list into a table and added a section for Analog signals. wikisysop
Line 1: Line 1:
 +====== Units of Measurement ======
  
 +Visual3D computes all [[Visual3D:Documentation:Visual3D_Signal_Types:LINK_MODEL_BASED_Data_Type|model based items]] using [[https://en.wikipedia.org/wiki/MKS_units|MKS units]], i.e. based on meters, kilograms and seconds. An exception to this rule are [[Visual3D:Documentation:Pipeline:Model_Based_Data_Commands:Joint_Angle#Units_for_Joint_Angles|joint angles]], which are represented in degrees.
  
-||+^ Quantity ^ Unit ^ 
 +|Distance | m | 
 +|Velocity | m/s | 
 +|Acceleration | m/s/s | 
 +|Mass | kg | 
 +|Force | N | 
 +|Energy | J | 
 +|Power | W | 
 +|Moment (Torque) | Nm | 
 +|Joint Angle | degrees | 
 +|Joint Angular Velocity | degrees/s | 
 +|Volume | m cubed |
  
-Visual3D computes [[Visual3D:Documentation:Visual3D_Signal_Types:LINK_MODEL_BASED_Data_Type|model based items]] using MKS units; eg. based on meters, kilograms and seconds. +===== Analog Units =====
- +
-An exception to this rule are [[Visual3D:Documentation:Pipeline:Model_Based_Data_Commands:Joint_Angle#Units_for_Joint_Angles|joint angles]], which are represented in degrees. +
- +
-\\ +
- +
- +
-Distance+
-Velocitym/s +
-Accelerationm/s^2 +
-MassKg +
-Force+
-Energy +
-Power +
-Moment (Torque) Nm +
-Joint Angle degrees +
-Joint Angular Velocity degrees/s +
-Volume = m^3+
  
 +Visual3D expects certain common [[visual3d:documentation:c3d_signal_types:c3d_format#c3d_parameter_format|parameters]] to be included in the ANALOG Section of the [[visual3d:documentation:c3d_signal_types:c3d_format|C3D file]] when [[visual3d:documentation:c3d_signal_types:analog_data_type|ANALOG]] data is present. If no unit parameter is available for an ANALOG signal then Visual3D defaults to interpreting the signal as being reported in Volts (V).
  
 +{{:visual3d_analog_parameters.png}}
  
  
visual3d/documentation/pipeline/model_based_data_commands/units_of_measurement.1718648491.txt.gz · Last modified: 2024/06/17 18:21 by sgranger